Projects

Recent Solar Installations

Browse recent ServoLuxe solar installations, from 5 kW home rooftops to 1 MW ground-mounted sites. Filter by homes or businesses.

  • 500+Systems installed
  • 10+Years in solar
  • 25 yrPanel warranty
  • 5.0 ★Customer rating

Project gallery

Explore systems by property type

Browse rooftop and ground-mounted examples across homes, businesses and larger sites. Capacity is shown on each image; the right system for your property is confirmed after reviewing your electricity use and site conditions.

  • Ground-mounted solar array on grass
    Ground-mount250 kW

    Ground-mounted solar array on grass

  • Solar panels on a tiled roof
    Rooftop8 kW

    Solar panels on a tiled roof

  • House with solar panels and a garden
    Villa10 kW

    House with solar panels and a garden

  • Wind turbines beside a solar field
    Hybrid site1 MW

    Wind turbines beside a solar field

  • Solar panels on a pitched roof
    Commercial120 kW

    Solar panels on a pitched roof

  • Installer on a roof covered in panels
    Rooftop5 kW

    Installer on a roof covered in panels

Project stories

Four installs, start to finish

Each of these had a constraint that shaped the design. The detail is what makes them useful to compare against your own roof.

Home

5 kW rooftop, Arera Colony, Bhopal

A family home running two air conditioners in summer, with a monthly bill around ₹6,500.

The constraint

A central water tank and a staircase room split the roof into two usable patches, and the meter board sat two floors below.

What we designed

Panels were split into two strings across both patches, feeding one 5 kW inverter. The DC run was routed in conduit down the service shaft to keep the facade clean.

Result

  • Bill fell to roughly ₹700–1,200 in most months
  • ₹78,000 PM Surya Ghar subsidy claimed and credited
  • Net meter installed by MPMKVVCL in the fourth week
Size
5 kW
Panels
9 × 555 W
Structure
Elevated GI
Commissioned
2023
Business

60 kW rooftop, school, Indore

A school with daytime loads across classrooms, labs and a water pump, closed only in the summer break.

The constraint

Work had to avoid term time, and the sheet roof needed a purlin check before any mounting was designed.

What we designed

Non-penetrating clamps across three roof sections, three 20 kW three-phase inverters for redundancy, and installation scheduled across the vacation window.

Result

  • About 60% of daytime consumption offset
  • Payback projected at under four years
  • Monthly generation report handed to the trustees
Size
60 kW
Inverters
3 × 20 kW
Mounting
Sheet clamps
Commissioned
2023
Business

250 kW captive plant, Dewas

A manufacturing unit with two shifts and a heavy motor load along AB Road.

The constraint

High fault level at the LT panel, and production could not stop for the changeover.

What we designed

Plant split across four roof blocks, HT-side metering with the DISCOM, and the changeover completed on a scheduled maintenance Sunday.

Result

  • Captive generation offsetting a large share of daytime units
  • Accelerated depreciation claimed in the first year
  • String-level monitoring feeding the plant's own dashboard
Size
250 kW
Connection
HT captive
Structure
Elevated GI
Commissioned
2024
Business

5 HP solar pump, Rewa district

A borewell irrigation set on a field with no reliable grid supply.

The constraint

The pump needed to run through the morning and evening, and there was no grid to fall back on.

What we designed

A ground-mounted 5 kW array with a solar pump controller, sized for the pump's head and duty cycle, with a small battery for controls.

Result

  • Diesel running cost removed entirely
  • Irrigation possible on the farmer's own schedule
  • Quarterly cleaning visit scheduled from Jabalpur
Array
5 kW
Pump
5 HP submersible
Mounting
Ground
Commissioned
2024

What we have learned

Three things that decide whether an install goes well

After several hundred projects, the same handful of issues decide whether a system performs and whether the customer feels well served. None of them are about panel brands.

Shade decides layout

Almost every project we survey has one obstruction that changes the panel arrangement. Mapping it first avoids a redesign later.

Roof condition matters as much as area

A large sheet roof with tired purlins needs work before panels, and that is quoted openly rather than discovered later.

Monitoring is the real handover

A system nobody watches drifts. Every project ends with app access and a baseline generation figure to compare against.

Behind every installation

The checks that go into each project

Whether it's a 3 kW rooftop or a 1 MW plant, every project goes through the same steps so it performs for 25 years.

Site survey

Shade, roof strength, orientation, earthing and the cable route are checked before any design is made.

Engineered design

Panel layout, string sizing and inverter choice are matched to your load and roof.

Safe installation

Certified crews, proper earthing, lightning protection and DC/AC protection devices on every job.

Testing and handover

Generation is tested, the net meter is commissioned, and you get documents and app access.

Want a system like these?

Leave your number and we'll call within one working day.